8845A/8846A 6.5 Digit Precision Multimeters

8845A/8846A 6.5 Digit Precision Multimeters
8845A/8846A 6.5 Digit Precision Multimeters
8845A/8846A 6.5 Digit Precision Multimeters
8845A/8846A 6.5 Digit Precision Multimeters

Precision and versatility for bench or systems applications

  • 6.5 digit resolution
  • Basic V dc accuracy of up to 0.0024 %
  • Dual display
  • 100 μA to 10 A current range, with up to 100 pA resolution
  • Wide ohms range from 10 Ω to 1 GΩ with up to 10 μΩ resolution
  • 2 x 4 ohms 4-wire measurement technique
  • Both models measure frequency and period
  • 8846A also measures capacitance and temperature
  • USB memory drive port (8846A)
  • Fluke 45 and Agilent 34401A emulation
  • Graphical display
  • Trendplot™ paperless recorder mode, statistics, histogram
  • CAT I 1000 V, CAT II 600 V
  • Three-year warranty

Are you looking to establish traceable calibration of factory test systems on the factory floor?

Read "Maintaining in-situ traceability on the factory floor with process metrology."

Read it now »

The Fluke 8845A and 8846A 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements, on the bench or in a system. These meters are both high performance and feature rich, yet also remarkably easy to use.

These digital multimeters perform the functions you would expect to see in a multifunction DMM, including measuring volts, ohms, and amps. Basic V dc accuracy of up to 0.0024 %, 10 A current range, and a wide ohms range give you an unbeatable combination of measurement capability.

You can also use the 8845A and 8846A to measure frequency and period. In addition, the 8846A measures temperature and capacitance. The functions of a counter, capacitance meter, and thermometer are built in for unparalleled versatility. Extend the meters’ utility even more with their graphical display modes, including TrendplotTM paperless recorder mode, statistics and histograms—features you won’t find on other multimeters.

Of course, these meters are also durable and dependable, features you expect from any Fluke meter. This unique combination of features and performance makes the 8845A and 8846A an unbeatable value for a wide variety of applications, including manufacturing test, research and development, and service.

 

Dual display and versatile graphical capabilities
The 8845A/8846A feature a unique dual display that allows you to measure two different parameters of the same signal from one test connection. To reveal signal quality issues like drift, intermittants and stability, view data as a real time trend plot or histogram, with the unique analyze mode. You won’t find graphical display capabilities like these on any other instrument in this class.

Perform 4-wire measurement with only two leads
Patented split terminal jacks for the 2 x 4 ohms function allow you to perform 4-wire measurements using only two leads instead of four. A special test lead accessory is available to enable you to establish the connection. You get excellent resolution and accuracy plus the convenience and ease of using a single pair of leads.

Multiple connectors give you maximum flexibility
Choose from several interfaces to connect the 8845A/8846A to a personal computer: serial, IEEE-488, and Ethernet come standard on both models. A USB device port is included on the 8846A meter for convenient data transfer to and from a PC via a portable USB storage device.

FlukeView® Software and drivers add PC power and application compatibility.
FlukeView Forms increases the power of your Fluke tool by enabling you to document, store and analyze individual readings or series of measurements, then convert them into professional-looking documents. Log live readings while connected to a PC or store, display and share readings in interactive forms, graphs and tables. Create customized, professional looking documents that can be printed or emailed. FlukeView Forms software includes easy-to-use standard forms.

Instrument programming drivers, DLL files and support information are included to get your test system up and running as quickly as possible.

FlukeView® Forms Basic
The Fluke 8845A/8846A ship with a free copy of FlukeView Basic. Transfer data points from your meter to your PC and use the two standard, noncustomizable forms to display your readings in table or graphical form. For a larger array of forms or to use FlukeView Forms Designer to customize your forms, upgrade to FlukeView Forms version 3.0 with FVF-UG.

Fluke 45 and Agilent 34401A emulation
The 8845A/8846A emulate operation and programming commands of the Fluke 45 and Agilent 34401. Emulation shortens the learning curve and makes it easy to fit the 8845A or 8846A into existing test systems.

Fluke support completes the equation of value
Like all Fluke products, the 8845A/8846A are built to provide years of dependable service. However, if you do need calibration or repairs, you can turn to our global network of direct and representative service centers strategically located around the world. Each offers a full range of support services.

Technical Specifications
Display VFD Dot Matrix
Resolution 6.5 Digits
V DC
Ranges: 100 mV to 1000 V
Max. Resolution: 100 nV
Accuracy: 8845A: 0.0035 + 0.0005 (% measurement + % of range)
  8846A: 0.0024 + 0.0005 (% measurement + % of range)
V AC
Ranges: 8845A: 100 mV to 750 V
  8846A: 100 mV to 1000 V
Max. Resolution: 100 nV
Accuracy: 8845A: 0.06 + 0.03 (% measurement + % of range)
  8846A: 0.06 + 0.03 (% measurement + % of range)
Frequency: 3 Hz to 300 KHz
Resistance
2x4 Wire: Yes
Ranges: 8845A: 100 Ω to 100 MΩ
  8846A: 10 Ω to 1 GΩ
Max. Resolution: 8845A: 100 μΩ
  8846A: 10 μΩ
Accuracy: 8845A: 0.010 + 0.001 (% measurement + % of range)
  8846A: 0.010 + 0.001 (% measurement + % of range)
A DC
Ranges: 100 μA to 10 A
Max. Resolution: 100 pA
Accuracy: 0.050 + 0.005 (% measurement + % of range)
A AC
Ranges: 8845A: 10 mA to 10 A
  8846A: 100 mA to 10 A
Max. Resolution: 8845A: 10 nA
  8846A: 100 pA
Accuracy: 0.10 + 0.04 (% measurement + % of range)
Frequency: 3 Hz to 10 kHz
Freq/Period
Ranges: 8845A: 3 Hz to 300 kHz
  8846A: 3 Hz to 1 MHz
Max. Resolution: 1 μHz
Accuracy: 0.01 %
Continuity/ Diode Test Yes
Capacitance
Ranges: 8846A: 1 nF to 0.1 F
Max. Resolution: 8846A: 1 pf
Accuracy: 8846A: 1 %
Temperature
Type: 8846A: Platinum RTD
Ranges: 8846A: -200 °C to +600 °
Max. Resolution: 8846A: 0.01 °
Accuracy: 8846A: 0.06 °
Math Functions
  NULL, Min/Max/Average, Std Dev
dB/dBm: Yes
Advanced Functions
Statistics/Histogram: Yes
Trendplot: Yes
Limit Test: Yes
Input Output
USB Memory: 8846A: USB memory drive port
Real Time Clock: 8846A: Yes
Interfaces: RS 232, IEE-488.2, Ethernet, USB (with optional adaptor)
Programming Languages/Modes: 8846A: SCPI (IEEE-488.2), Agilent 34401A, Fluke 45

 

General Specifications
Weight 3.6 kg (8.0 lbs)
Dimensions 88 mm x 217 mm x 297 mm (3.46 in x 8.56 in x 11.7 in)
Calibration Documentation 17025 accredited report of calibration included
Safety Designed to comply with IEC 61010-1:2000-1, UL 61010-1A1, CAN/CSA-C22.2 No. 61010.1, CAT I 1000V/CAT II 600V
Warranty Three years
Model Name Description
Fluke 8845A

6.5 digit Precision Multimeter, 35 ppm
Includes:
TL71 Test Lead Set, Premium DMM
LCI Line Cord
USB to RS232 Cable Adapter
Statement of Calibration Practices
WEEE Information Sheet
Warranty Information
Programmer, Users and Service Manuals (CD-ROM)
FlukeView Forms – Basic for 8845/8846

Fluke 8845A/SU

6.5 digit Precision Multimeter, 35 ppm (software and cable)
Includes:
FlukeView Forms Software Upgrade
USB to RS232 Cable Adapter  

Fluke 8846A

6.5 digit Precision Multimeter, 24 ppm USB mem
Includes:
TL71 Test Lead Set, Premium DMM
LCI Line Cord
USB to RS232 Cable Adapter
Statement of Calibration Practices
WEEE Information Sheet
Warranty Information
Programmer, Users and Service Manuals (CD-ROM)
FlukeView Forms – Basic for 8845/8846

Fluke 8846A/SU

6.5 digit Precision Multimeter, 24 ppm USB mem (software and cable)
Includes:
FlukeView Forms Software Upgrade
USB to RS232 Cable Adapter  

Accessories common to all models:

Accessory Description
FVF-UG

FlukeView Forms for 8845/8846 Software Upgrade

FVF-SC5

FlukeView Forms, Basic Software
Includes:

  • CD for FlukeView Forms Basic
  • Users manual, registration card, and software license agreement
FVF-SC4

FlukeView Forms with Cable for 8845/8846

Y8022

Shielded IEEE-488 Cable, 2m

Y8021

Shielded IEEE-488 Cable, 1m

RS43

RS-232 Cable (RS43, 2 m)

Y8846S

Rack Mount Kit, Single

Y8846D

Rack Mount Kit, Dual, 19-inch

884X-USB

USB to RS232 Cable Adapter

884X-ETH

Ethernet Interface Cable

884x-CASE

Molded Plastic Case

TL80A

Basic Electronic Test Lead Set

TL2x4W-PTII

2X4-Wire Ohms Test Lead

884X-SHORT

4-Wire Short

884X-RTD

100 Ohm RTD Temperature Probe

8845A-TPIT

Test Probe IC Tip Set (red and black)

8845A-EFPT

Extended Fine Point Tip Adapter Set (red and black)

TL910

Electronic Test Probes

TP912

Replacement Tips for TL910

TL71

Test Lead Set

TL2X4W-TWZ

2X4-Wire Ohms Tweezers Test Leads

884X-1G

USB Memory 1 GB

884X-512M

USB Memory 512 MB

FUSE

Fuse, 440 mA, 1000 V, Fast, 0.406 in x 1.375 in, Bulk

FUSE
FUSE, 11 A, 1000 V, Fast, 406 in x 1.5 in, Bulk   
FlukeView Forms

FlukeView Forms Software

Silver CarePlan

Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Product Manuals
application/pdf icon8845A /8846A Safety Information (62.59 KB)
application/pdf icon8845A /8846A Safety Information Supplement (231.48 KB)
application/pdf icon8845A /8846A Safety Information (Spa) (64.38 KB)
application/pdf iconSatement of Memory of Volatility (29.37 KB)
application/pdf icon8845A/8846A Calibration Manual (1.62 MB)
application/pdf icon8845A/8846A Calibration Manual Supplement (187.31 KB)
application/pdf icon8845A/8846A Programmers Manual (Eng) (923.05 KB)
application/pdf icon8845A/8846A Programmers Manual Supplement (231.61 KB)
application/pdf icon8845A/8846A Users Manual (Eng) (1.75 MB)
application/pdf icon8845A/8846A Users Manual Supplement (128.58 KB)
application/pdf icon8845A/8846A Users Manual (chi) (2.06 MB)
application/pdf icon8845A/8846A Users Manual (cze) (1.95 MB)
application/pdf icon8845A/8846A Users Manual (fre) (1.9 MB)
application/pdf icon8845A/8846A Users Manual (ger) (1.89 MB)
application/pdf icon8845A/8846A Users Manual (ita) (1.83 MB)
application/pdf icon8845A/8846A 取扱説明書(日本語) (2.09 MB)
application/pdf icon8845A/8846A Users Manual (pol) (1.96 MB)
application/pdf icon8845A/8846A Users Manual (rus) (2.11 MB)
application/pdf icon8845A/8846A Users Manual (spa) (1.87 MB)
application/pdf icon8845A/8846A Users Manual (tur) (2.05 MB)
application/pdf icon8845A/8856A Declaration of Conformity (616.15 KB)
application/pdf iconLinux GPL GNU GENERAL PUBLIC LICENSE (140.29 KB)
application/pdf iconLinux GPL GNU LESSER GENERAL PUBLIC LICENSE (150.52 KB)
Application Notes
application/pdf iconCharacterizing & Disciplining Electrical Calibrator Instrumentation to Improve Test Accuracies & Measurement Uncertainties (154.06 KB)
application/pdf icon2x4 Wire Resistance Simplifies Precision Measurements (English) (83.68 KB)
application/pdf iconWiderstandsmessung mit 2 x 4 Leitungen vereinfacht hochpräzise Messungen (German) (547.48 KB)
application/pdf iconSimplification de la mesure de précision de la résistance en 2x4 fils (French) (549.5 KB)
application/pdf iconLa medida de resistencia de 2x4 hilos simplifica las medidas de precisión (Spanish) (546.93 KB)
application/pdf iconLa resistenza a 2x4 fili semplifica le misure di precisione (Italian) (547.48 KB)
application/pdf iconData Logging on the Fluke 884X with TrendPlot™ (English)
application/pdf iconDatenprotokollierung auf dem Fluke 884X mit TrendPlot (German)
application/pdf iconEnregistrement de données sur le Fluke 884X avec TrendPlot (French)
application/pdf iconRegistro de datos en el Fluke 884X con TrendPlot (Spanish)
application/pdf iconRegistrazione dati su Fluke 884X con TrendPlot (Italian)
application/pdf iconFluke 8845A/8846A Statistics and Histograms (English)
application/pdf iconFluke 8845A/8846A Statistiken und Histogramme (German)
application/pdf iconStatistiques et histogrammes avec le Fluke 884x (French)
application/pdf iconEstadísticas e histogramas de Fluke 8845A/8846A (Spanish)
application/pdf iconStatistiche e istogrammi Fluke 8845A/8846A (Italian)
application/pdf iconUnderstanding Specifications for Precision Multimeters
application/pdf iconUnderstanding Specifications for Precision Multimeters (448.83 KB)
Brochures
application/pdf iconFluke 8845A/8846A Digital Multimeters (1.63 MB)
application/pdf iconFluke 8845A/8846A Digitalmultimeter (German) (692.9 KB)
application/pdf iconFluke 8845A/8846A Multimètres numériques (French) (686.63 KB)
application/pdf iconFluke 8845A/8846A Multímetros digitales (Spanish) (693.06 KB)
application/pdf iconFluke 8845A/8846A Multimetri digitali (Italian) (685.9 KB)
application/pdf iconFluke Bench Multimeters (8845A/8846A and 8808A) (4.28 MB)
application/pdf iconFluke Präzisions-Blockkalibratoren (8845A/8846A/8808A) (German) (1.3 MB)
application/pdf iconMultimètres de banc Fluke (8845A/8846A/8808A) (French) (1.28 MB)
application/pdf iconMultímetros de banco de Fluke (8845A/8846A/8808A) (Spanish) (1.28 MB)
application/pdf iconMultimetri Fluke da banco (8845A/8846A/8808A) (Italian) (1.24 MB)
application/pdf iconPetrochemical industry calibration solutions (2.59 MB)
application/pdf iconРешения по калибровке для нефтехимической промышленности (Russian) (2.97 MB)
application/pdf iconSoluciones de calibración de la industria petroquímica (Spanish) (2.9 MB)
application/pdf iconSoluções de calibração do setor petroquímico (Portuguese) (2.91 MB)
application/pdf iconKalibrierlösungen für die petrochemische Industrie (German) (2.39 MB)
application/pdf iconSolutions d'étalonnage pour l'industrie pétrochimique (French) (2.38 MB)
application/pdf iconPharmaceutical industry calibration solutions (2.28 MB)
application/pdf iconРешения по калибровке для фармацевтической промышленности (Russian) (3.62 MB)
application/pdf iconSoluciones de calibración para la industria farmacéutica (Spanish) (4.57 MB)
application/pdf iconSolutions d'étalonnage pour le secteur pharmaceutique (French) (5.52 MB)
application/pdf iconKalibrierlösungen für die Pharmaindustrie (German) (5.6 MB)
application/pdf iconSoluções de calibração do setor farmacêutico (Portuguese) (3.54 MB)
application/pdf iconPower and utilities industry calibration solutions (5.03 MB)
application/pdf iconSoluciones de calibración de la industria de energía y servicios (Spanish) (6.52 MB)
application/pdf iconРешения в области калибровки приборов для измерения при производстве электроэнергии и эксплуатации инженерно-технических систем (6.98 MB)
application/pdf iconSoluções de calibração do setor de serviços públicos e energia (Portuguese) (6.97 MB)
application/pdf iconKalibrierungslösungen für die Energie- und Versorgungsindustrie (German) (5.91 MB)
application/pdf iconSolutions d'étalonnage pour le secteur de la distribution d'énergie (French) (5.9 MB)
Demo Software
FlukeView® Forms Demo/Reader Software Downloads
Data Sheets
application/pdf icon8845A/8846A Digital Multimeters Accessory Guide (762.92 KB)
Instruction Sheets
application/pdf iconTL2X4W-TWZ 2x4-Wire Ohms Tweezers Test Leads Instruction Sheet (118.59 KB)
application/pdf iconY8846S/Y8846D Rack Mount Kit Instruction Sheet (512.86 KB)
Specifications
application/pdf iconFluke 8845A/8846A Digital Multimeters Extended Specifications (303.61 KB)
Papers / Articles