molbox1+ Flow Terminal

molbox1+ Flow Terminal
molbox1+ Flow Terminal
molbox1+ Flow Terminal
molbox1+ Flow Terminal
molbox1+ Flow Terminal
molbox1+ Flow Terminal
Request a quote
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

± 0.125 % of reading—lowest uncertainty for gas flow calibration

The new molbox1+ flow terminal from Fluke Calibration represents a significant update to the molbloc/molbox gas flow calibration system. molbox1+ combined with molbloc-L (to 100 slm) and molbloc-S (to 5000 slm) flow elements enables you to achieve the lowest uncertainty available for gas flow meter calibration and controller calibrations. A special configuration, molbox1+S, allows you to use molbloc-S sonic nozzle flow elements at higher pressures than were previously possible, greatly extending their usable flow range.

A molbloc/molbox1+ gas flow calibration system is the ideal solution for gas flow meter calibration, as well as for calibrating thermal mass flow controllers (MFCs), rotameters, turbine meters, bubble meters, and other flow measurement devices. With real-time measurements, no moving parts and supported by traceable calibration in several different gases and operating pressures, molbloc/molbox can handle virtually any calibration application without compromise. molbloc/molbox systems are widely used in many industries, including pharmaceuticals, semiconductors, aerospace, environmental monitoring, energy production, reference gas blending, and research and standards laboratories.

Already own a molbloc/molbox flow system? Upgrading to the newest capabilities is easy and economical. For more information click on the program description link:

Upgrade Program Description

Features at a glance

± 0.125 % of reading uncertainty on mass flow measurements with molbloc-L and molbloc-S elements with premium calibrations

  • molbox1+S configuration gives extra rangeability with molbloc-S elements without requiring vacuum pumps
  • Now use any molbloc element for both high and low pressure applications in the same gas
  • Even more robust internal pneumatic design
  • Full suite of software automation products and hardware accessories to create a complete gas flow calibration system—including new COMPASS® for Flow calibration assistance software

Unparalleled uncertainty specifications

molbox1+ innovations enable the molbloc/ molbox1+ system to achieve the lowest gas flow measurement uncertainties in the industry. The lower uncertainty is made possible by several key improvements, including:

  • Use of Fluke Calibration's exclusive quartz reference pressure transducer (Q-RPT) technology to precisely measure both absolute and differential pressure. molbox1+ Q-RPTs are specially characterized sensors benefitting from the same technology used in Fluke Calibration’s pressure transfer standards.
  • Premium molbloc calibrations linearize molbloc flow output to better capitalize on existing precision and repeatability.
  • Expanded molbloc modelization enables improved performance of molbloc-L laminar flow elements across their range of operating pressures.
  • Reduced uncertainty on gas properties utilizing data from NIST Reference Fluid Thermodynamic and Transport Properties Database (REFPROP).
  • Continued improvements in Fluke Calibration’s molbloc calibration chain, based on fundamental massand time-based mass flow measurements using Fluke Calibration’s own dynamic Gravimetric Flow Standard.

Two levels of molbloc flow element calibration are now available to let you balance uncertainty and cost:

  • Premium: ± 0.125 % of reading flow measurement uncertainty (with molbox1+)
  • Standard: ± 0.2 % of reading flow measurement uncertainty (with molbox1 or molbox1+)

New molblocs are eligible for either calibration type. Existing molblocs are compatible with molbox1+ at ± 0.2 % of reading uncertainty with no changes required. See below for details on upgrade service to existing molblocs to allow premium calibration and measurement specifications.

The molbloc/molbox system has stood the test of time for flow meter calibration since the early 1990’s, used in many demanding calibration laboratories, intercomparisons and government organizations worldwide. Fluke Calibration’s uncertainty specifications are conservative and backed by a thorough uncertainty analysis and metrology support. Fluke Calibration’s innovation and design is continually aimed at making sure our products deliver specifications that can be realized by the user, not under best case conditions but in your real-world application.

molbox1+S sonic nozzle calibration device expands rangeability—without vacuum pumps molbox1+S is a special configuration of molbox 1+ that enables you to cover a wide range (10:1 range turndown) with molbloc-S sonic nozzle flow elements, without requiring costly vacuum pumps. molbox1+S sonic nozzle calibration device is available with upstream Q-RPT pressure range up to 2 MPa (300 psia) to allow molbloc-S elements to be conveniently used over a wide flow range upstream of flow meters being tested at atmospheric pressure, a common application. This extra rangeability makes it simple to configure a calibration system using fewer molbloc elements and minimal accessories. It also greatly extends the range of your existing molbloc-S elements when a high pressure molbloc calibration is added.

molbloc-S range example with device under test at atmospheric pressure

Molbloc-S element

Usable range with SP calibration and molbox1 A700K

Usable range with HP calibration and molbox1+S A2M

1E2-S

15 to 50 slm*

20 to 200 slm

5E2-S

67 to 250 slm*

100 to 1000 slm

*Minimum usable flow of molbloc-S elements with SP calibrations are limited by back pressure requirements for sonic flow when used upstream of a device at atmospheric pressure. Flow values are in standard liters per minute referenced to 0 °C.

molbox1+S is designed for use with molbloc-S sonic nozzle calibration devices and therefore is configured for absolute pressure measurement only, reducing its cost. It also reduces flow system complexity and overall cost, as well as ongoing recalibration costs.

Use the same molbloc in multiple applications

Multiple molbloc calibrations are now supported for each gas. This means that you can now have a molbloc calibrated separately for use both at high pressure (upstream of the device under test) and low pressure (downstream of the device under test) to support different applications instead of requiring two molblocs or manually loading separate molbloc calibration files. All calibrations are stored on the molbloc EEPROM and the user simply selects the calibration type from the molbox1+ front panel or via molbox1+ remote interface.

COMPASS® for molbox and new COMPASS® for Flow software add automation and more

COMPASS calibration assistance software takes molbloc/molbox to the next step in automating calibrations. COMPASS and a personal computer work with molbloc/molbox to create a modern, full function, turnkey system for calibrating and testing flow devices.

COMPASS sets up device under test (DUT) records (also known as unit under test), defines and associates test procedures with DUTs, runs tests, acquires reference and test data, produces standard and custom calibration reports. Mass flow device gas correction factors and gas density corrections for volumetric devices like rotameters are easily supported, with options to dynamically calculate the corrected flow using automatic input of pressure and temperature measurements. All reference, DUT and test data are collected and stored in standard delimited files that can be easily downloaded to other applications.

A new version of the software, COMPASS for Flow, brings features to flow calibration that were previously only available in Fluke Calibration’s COMPASS for Pressure software. These include: 

  • Ability to export data to Fluke MET/TRACK® software.
  • Enhanced support for devices under test requiring custom calculations on output indications, special communications support and calibration of multiple devices at once.
  • Macro support to handle almost unlimited test system automation.
  • More complete and flexible support for accessory devices like MFC-CB (DHI mass flow controller control box).

Upgrading is easy

Upgrading from molbox1 to molbox1+ is economical and easy. A hardware and software upgrade can be performed at Fluke Calibration’s Phoenix factory. To upgrade and achieve the new specifications and features offered by molbox1+ the following steps are performed on your system at Fluke Calibration.

  1. molbox1+ hardware/software changes. Any required parts are changed to make your molbox materially identical to a factory produced molbox1+. The molbox is flashed to v6.0 embedded software. Two options are available: Upgrade your existing molbox1 to meet molbox1+ specifications, or trade up to a new molbox1+, capturing savings by reusing a few key parts.
  2. Q-RPT characterization of molbox1 internal pressure transducers. Both existing internal pressure transducers are used in the new molbox1+. Extensive characterization of the transducers enhances their precision and ensures they meet molbox1+ specifications.
  3. molbloc hardware updates. molbloc-L or molbloc-S elements to be used with the molbox1+ require hardware modifications to support the premium uncertainty specification and a new data structure.
  4. New molbloc gas calibrations. molblocs are fully modeled and calibrated following hardware updates to realize the benefits of the enhanced gas property data used in molbox1+, Fluke Calibration’s improved calibration chain and new molbloc linearization and modeling techniques.

The entire system will be upgraded and returned to you with new specifications and calibration certificates at a fraction of the cost of a new system.

General specifications

Power requirements

85 V ac to 264 V ac, 47 Hz to 440 Hz, 18 VA max consumption

Normal operating temperature range

15 °C to 30 °C (59 °F to 86 °F)

Storage temperature range

-20 °C to 70 °C (-4 °F to 158 °F)

Vibration

Meets MIL-T-28800D

Weight

6.8 kg (15 lb) max

Dimensions (WxHxD)

32 cm x 12 cm x 30 cm (12.6 in x 4.7 in x 11.8 in) approx.

Communication ports

RS-232 (COM1), RS-232 (COM2), IEEE-488.2

Pressure connections (molbox1+ and molbloc)

Quick connectors equivalent to Swagelok® QM Series (SS-QM2-B200)

Flow ranges

<1 sccm to >5000 slm

See separate molbloc-L and molbloc-S range tables

Flow measurement rate

1 second

Gases supported
(Consult your sales representative for a current list of gases available for factory molbloc calibration.)

Nitrogen (N2), Air, Argon (Ar), Carbon Monoxide (CO), Helium (He), Oxygen (O2), Carbon Dioxide (CO2), Carbon Tetrafluoride (CF4), Ethane (C2H6), Ethylene (C2H4), Fluoroform (CHF3), Hexafluoroethane (C2F6), Hydrogen (H2), Methane (CH4), Nitrous Oxide (N2O), Propane (C3H8), Sulfur Hexafluoride (SF6), Butane (C4H10), Octafluorocyclobutane (C4F8), Xenon (Xe)

Valve driver option

(8) 12 V outputs

Each output can sink 500 mA at 12 V, max 1 Amp total

MFC control option (analog input/output)

Nominal voltage range:

0 V dc to 6 V dc input

0 V dc to 5 V dc output

Nominal current range:

4 mA to 20 mA input

4.01 mA to 20 mA output

Accuracy:

± 0.1 % FS (set), ± 0.05 % FS (measure)

Pressure measurement

Type

Q-RPT Characterized Quartz Reference Pressure Transducers –Oscillating quartz crystal with mechanical bellows

Calibrated pressure range (full scale)

A700K: 0 to 600 kPa absolute (0 to 87 psia)
A350K: 0 to 300 kPa absolute (0 to 44 psia)
S A1.4M (molbloc-S only):  0 to 1.2 MPa absolute (0 to 174 psia)
S A2M (molbloc-S only):  0 to 2 MPa absolute (0 to 290 psia)

Measurement uncertainty (one-year)

Absolute pressure4
± (0.01 % of reading or 0.003 % Q-RPT span,  whichever is greater)

Differential pressure (A700K with Tare)
± (8.4 Pa (0.0012 psi) or 0.032 % ΔP, whichever is greater)

Differential pressure (A350K with Tare)
± (4.2 Pa (0.0006 psi) or 0.026 % ΔP, whichever is greater)

Temperature measurement

Type

molbloc PRTs with molbox1+ Ohmic Measurement System

Range (FS)

0 to 40 °C

Resolution

0.01 °C

molbloc PRT precision

± 0.02 °C (15 to 30 ˚C)

On-board

Reference resistor
100 and 110 Ω ± 0.01 %, stability < 25 ppm/year 

Ohmic measurement
± 0.02 % of reading (15 °C to 30 °C)

Flow measurement

With molbloc-L laminar flow elements

 

Standard molbloc calibration

Premium molbloc calibration

Range

0 to 100 % molbloc full scale

0 to 100 % molbloc full scale

Resolution

0.0015 % FS

0.0015 % FS

Precision1

± 0.07 % of reading,
± 0.007 % FS under 10 % FS

± 0.07 % of reading,
± 0.007 % FS under 10 % FS

Stability (one-year)2

± 0.09 % of reading,
± 0.009 % FS under 10 % FS

± 0.03 % of reading,
± 0.003 % FS under 10 % FS

Measurement uncertainty3
(For any gas for which the molbloc in use is calibrated)

± 0.2 % of reading,
± 0.02 % FS under 10 % FS

± 0.125 % of reading,
± 0.0125 % FS under 10 % FS

With molbloc-S sonic nozzle flow elements

 

Standard molbloc calibration

Premium molbloc calibration

Range

10 % to 100 % molbloc full scale

10 % to 100 % molbloc full scale

Resolution

0.0015 % FS

0.0015 % FS

Precision1

± 0.06 % of reading

± 0.06 % of reading

Stability (one-year)2

± 0.05 % of reading

± 0.03 % of reading

Measurement uncertainty3
(For any gas for which the
molbloc in use is calibrated)

± 0.2 % of reading

± 0.125 % of reading4

1 Precision: Combined linearity, hysteresis, repeatability.

2 Stability: Maximum change in zero and span over specified time period for typical molbox and molbloc used under typical conditions. As stability can only be predicted, stability for a specific molbox and molbloc should be established from experience.

3 Measurement uncertainty: Maximum deviation of the molbox1+ flow indication from the true value of the flow through the molbloc including precision, stability and Fluke Calibration. For a complete description of uncertainties see technical note 2011TN06B UNCERTAINTY ANALYSIS FOR FLOW MEASURED BY molbloc-L AND molbloc-S MASS FLOW TRANSFER STANDARDS.

4 With regular use of Autozero. Add 0.005 % of Q-RPT span for one year without use of  AutoZero, (translates to 0.005 % FS for molbloc-S, does not significantly affect molbloc-S standard calibration or molbloc-L uncertainty.)

All uncertainty specifications reported at k=2

Model Name Description
molbox1+ A700K

700 KPa (100 psia) Flow Terminal
For molbloc-L and molbloc-S

molbox1+ A350K

350 KPa (50 psia) Flow Terminal
For molbloc-L and molbloc-S

molbox1+S A2M

SONIC 2 MPa (300 psia) Flow Terminal
molbloc-S only terminal

molbox1+S A1.4M

SONIC 1.4 MPa (200 psia) Flow Terminal
molbloc-S only terminal

Accessories common to all models:

Accessory Description
Rack Mount Kit

Rack mount kit for standard 19 in. rack

MFC Control Option

Set and read analog voltage and current MFCs. Optional board is built-into molbox1+ and connector is on rear panel. Delivered with MFC cable and connection kit.

Priority Gold Instrument CarePlan

Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Product Manuals
application/pdf icon MFC Interface Cable Reference (100.98 KB)
application/pdf icon molbox1+™/molbox1+S molbloc® Terminal Operation and Maintenance Manual (1.66 MB)
application/pdf icon molbox1+™/molbox1+S molbloc® Terminal Operation and Maintenance Manual Supplement (67.75 KB)
application/pdf icon Parts Included in molbox1/MPC1 Rack Mount Kit (114.63 KB)
application/pdf icon Q-RPT Replacement Kit Instruction Sheet (787.41 KB)
application/pdf icon Use of molbox ohmic calibration cable Instruction Sheet (277.61 KB)
Application Notes
application/pdf icon Four Steps to More Effective Gas Flow Calibration (1.33 MB)
application/pdf icon Quatre étapes pour un étalonnage plus efficace des débits de gaz (2.07 MB)
application/pdf icon Vier Schritte für eine effektivere Massendurchflusskalibrierung (2.08 MB)
application/pdf icon Hardware Setup and Application Notes for Calibrating FTS Device with molbloc/molbox™ (102.49 KB)
application/pdf icon Mass flow versus volume flow in gas flow calibration (769.59 KB)
application/pdf icon Process Calibration Tools: Flow Applications (1.01 MB)
application/pdf icon How to calibrate reference pressure transducers with COMPASS® for Pressure Software (4.31 MB)
Data Sheets
application/pdf icon molbloc-L ranges data sheet (1.28 MB)
application/pdf icon molbloc-S ranges data sheet (172.57 KB)
application/pdf icon molbox1+™ Flow Terminal Data Sheet (1.92 MB)
Software
COMPASS for Flow PC Based Software Download/Upgrade
COMPASS for molbox PC Based Software Download/Upgrade
Firmware
molbox1+ or molbox1+S v6.01 Embedded Software
LabView Drivers
LabVIEW Drivers, Pressure and Flow Calibration Products
Papers / Articles
application/pdf icon molbox1+ Upgrade Program Description (82.33 KB)
Video
molbox/molbloc Mass Flow Calibration Solution Demo Video
molbox: Gas Flow Calibration System
On-Demand Webinars
How to calibrate rotameters and other density-dependent flow meters
Press Releases
New DHI molbox1+ flow terminal offers the lowest uncertainties for gas flow calibration
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
    • Handheld Test Tools
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • "How To" Seminars
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Resource Centers
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Safety Data Sheets (SDS)
    • Safety, Service, and Product Notices
    • Software Downloads
    • Tools
      • PT100 Calculator
      • PT100 Table Generator
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
    • Why buy Fluke Calibration ?
Home|Products|Flow Calibration|Gas Flow Standards|molbox1+ Flow Terminal

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

Products

  • Product index
  • New products
  • Where to buy
  • Request a quote

Services

  • Calibration and repair
  • About Fluke Calibration
  • Service centers
  • Software downloads

Resources

  • Catalogs
  • Manuals
  • Web seminars
  • Subscribe to e-news
  • Supplier Handbook

Company

  • Contact us
  • About Fluke Calibration
  • Why choose us
  • Other Fluke companies
©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Terms of Use
  • Terms of Sale