• Other Fluke companies:
  • Fluke
  • Fluke Biomedical
  • Fluke Networks
  • Fluke Process Instruments
See more Fluke brands
Accelix Amprobe Beha-Amprobe Comark Emaint Landauer Pacific Laser Systems Pomona RaySafe Schad
Home
Precision, Performance, Confidence.
Fluke Calibration: US
  • Register
  • Log in
  • Contact Us

US - English [Change]

 

Get Quote

910/910R GPS Frequency Standards

Frequency Standard
GPS Frequency Reference
GPS Frequency Standards
GPS Frequency Standard
Frequency Standard
GPS Frequency Reference
GPS Frequency Standards
GPS Frequency Standard
Request a quote
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

GPS Frequency Standard - The cesium controlled frequency standard that uses GPS technology and connectivity to provide primary standard traceability from any location

The 910 and 910R GPS frequency references are fully traceable and extremely accurate gps frequency standards and are ideally suited for use in many applications, including telecommunications, calibration and automatic test systems.

Both the 910 and 910R deliver a precision frequency and pulse-per-second time reference which, with its many connectivity options, can be installed, monitored and managed from virtually any location. Both models receive their long-term frequency stability from the built-in cesium standards in the GPS-satellite array, yet can also provide a very high short-term stability from the built-in oven controlled crystal oscillator (OCXO) or rubidium oscillator (Rb).

Download Fluke Calibration GPSview Software

  • Unique traceability feature means no more re-calibrations
  • Two high-stability models to meet your application, and fit your budget
  • Up to 13 outputs, maximizing cost efficiency
  • Central or remote monitoring, management and data collection, using the 910/910R Ethernet-port
  • Two high-stability operating modes to suit your application
  • Designed for portability too
  • GPSView Software

Unique traceability feature means no more re-calibrations

Off-air frequency standards have existed for several years. But until now, they all have had the same internal architecture (figure 1). The unit is, in effect, a "black box," with an antenna input and a frequency output.

The local oscillator's control process (disciplining) is hidden from the user. Typically, users have used another frequency reference (for example, a rubidium standard), a timer/counter and a PC for logging the deviation between the "black box" and the frequency reference.

The concept of traceability requires an unbroken chain of comparisons to international standards, on a continuing basis, where all comparisons produce documented results with stated uncertainty.

Now, for the first time, a documenting frequency comparator and a very stable secondary standard are united within the same instrument together with the GPS receiver.

The received GPS signal is measured continuously against the local oscillator. Phase and frequency deviation is stored internally and can at any time be transferred to any PC directly from the 910/910R or, via the optional Ethernet interface, from or to almost anywhere. Then by using the GPSView TM software supplied with every model, a printout of the traceability record can be obtained. The unbroken calibration history chain — day by day — is maintained in the non-volatile memory for several years, with the current 24-hour mean offset being displayed continuously on the front panel's LCD display.

Such unique traceability to primary standards means that the 910 and 910R GPS frequency standards never need to be away for re-calibration. Thanks to this design, the very high stability built-in rubidium or OCXO oscillator is continuously calibrated to the primary frequency standards in the US Naval Observatory and ultimately to UTC, in both operating modes, disciplined or manual hold-over.

Two high-stability models to meet your application, and fit your budget

Fluke Calibration offers two standard models in its GPS frequency standards range; the very-high stability 910R GPS frequency standard with its built-in rubidium atomic clock as the local oscillator, and the affordable 910 GPS frequency standard with its high stability local oven controlled crystal oscillator.

Up to 13 outputs, maximizing cost efficiency

Both models come with one 5 MHz and five 10 MHz sinewave outputs as standard. A 1 pulse-per-second output is also included.

If your application requires more outputs — for example, if several other instruments need to be supplied from the same frequency standard — option 70 allows you to mount five more 10 MHz outputs. Alternatively, option 72 allows you to expand your instrument to give five extra 2.048 MHz outputs, which is particularly useful in many telecoms applications. Option 73 provides five extra 13 MHz outputs, the standard frequency for GSM base station master clocks. Another variant on output configuration is offered through option 71, which gives the instrument an additional four sine wave outputs of 10 MHz, 5 MHz, 1 MHz and 0.1 Hz, plus a 0.1 MHz square wave output. And finally, option 75 allows you to define your own pulse frequency output.

Central or remote monitoring, management and data collection, using the 910/910R Ethernet-port.

The 910 and 910R GPS frequency standards can both be fitted with an optional Ethernet communication interface (option 76) which enables on-line access. Using the GPSView TM software supplied, it is possible to monitor both instrument and GPS status, or even collect calibration data, via the internet or any Local Area Network.

With Ethernet interface connectivity, distances to which data can be transmitted become unlimited, unlike that of any standard GPIB or RS232 interface, thereby allowing the 910/910R GPS frequency standard to be monitored from practically anywhere.

This means that the metrologist or lab technician no longer requires a 'floating' laptop PC to directly perform instrument management tasks, as this can now be achieved from any desktop PC, from any location inside or outside the calibration laboratory. It also allows data from multiple instruments to be simultaneously viewed in real time.

Two high-stability operating modes to suit your application

Most users prefer automatic adjustment (known as disciplining) of their frequency standard, to fully eliminate long-term frequency changes (aging). This disciplined mode is also the default mode in the 910 and 910R. As long as there is a valid satellite signal, the internal local oscillator is monitored and adjusted and the mean 24-hour frequency offset is always virtually zero. However, in this mode, the inherent short-to-medium term stability of all local oscillators, except rubidium, is compromised. This is true for all GPS frequency references. The received GPS signal has relatively large short-term frequency variations, due to variations in atmospheric conditions. This means that when using the received GPS signal for disciplining the 910 (OXCO), the stability is reduced a little for averaging times of 100 s to 1000 s.

In this mode, the frequency deviation between the internal timebase oscillator and the received GPS-signal is used to continuously adjust the oscillator (disciplining). The resulting frequency offset and adjustment data is stored in non-volatile memory every 24 hours, to enable printout of the traceability record. The actual frequency offset (24-hour mean value) is calculated and displayed on the front panel.

Some applications demand superior short-medium term stability, especially for jitter and wander measurements in digital telecommunication networks.

The unique Manual Hold-Over Mode makes it possible to switch over temporarily from Disciplined to Hold-Over Mode during the actual measurement, thereby achieving a superior frequency accuracy at the start of the measurement and a superior stability through the measurement. Here, the internal oscillator is not adjusted. This mode is normally automatically entered when there is no usable received GPS-signal. This mode can also be selected manually by activating the Manual Hold-Over Key. If Manual Hold-Over is set together with a valid received GPS signal, the actual frequency offset is calculated, displayed and stored in non-volatile memory every 24 hours.

For the ultra-stable rubidium oscillator in the 910R, there is no measurable difference between the stability in Disciplined and Hold-Over mode, for averaging times up to 1000 s.

Designed for portability too

When using Manual Hold-Over Mode, the 910 or 910R act as a stand-alone OCXO or rubidium frequency standard. This means that one typical drawback of a GPS receiver, lack of portability, is eliminated. A typical GPS receiver needs hours to lock after a change of location, whereas the 910 and 910R are up and running after just ten minutes.

GPSView Software

GPSView is a Windows 95/98/ 2000/NT program that communicates with the GPS-controlled frequency standard. Its main purpose is to provide a traceable calibration document based on the 24 hour frequency offset values, internally stored in the non-volatile memory of model 910/910R (figure 3).

It is only necessary to download data to a PC to the 910/910R once every second year to obtain an unbroken traceability chain since first use. For performance analysis over a shorter period and for short-term phase variation, data can be obtained over the latest forty-day period.

From GPSView, the user can control the operating mode (Disciplined or Hold-Over), and lock the front panel to prevent unintended change via the Manual Hold-Over Key. The user can also set the optional pulse output frequency and duty cycle.

General Specifications
Operating Modes
Disciplined Mode: The frequency deviation between the internal timebase oscillator and the received GPS-signal is used to continuously adjust the oscillator (disciplining). The resulting frequency offset and adjustment data is stored in non-volatile memory every 24h, to enable printout of the traceability record. The actual frequency offset (24h mean value) is calculated and displayed on the front panel.
Hold-over Mode: The internal oscillator is not adjusted. This mode is normally automatically entered when there is no usable received GPS-signal. This mode can also be selected manually be activating the Manual hold-over key. If Manual hold-over is set together with a valid received GPS signal, the actual frequency offset is calculated and displayed plus stored in non-volatile memory every 24h.
Frequency stability - locked to GPS 910R (GPS-Rb)
Frequency offset (24h mean):  <1x10-12*
Short term (Allan dev.):  <1 x 10-12 (t = 100s)
   <3 x 10-12 (t = 100s)
   <1 x 10-11(t = 10s)
   <3 x 10-11 (t = 1s)
Warm up (+25°C):  20 mins to lock
 *At temperatures 23°C + 3°C
Frequency stability - locked to GPS 910 (GPS-OCXO)
Frequency offset (24h mean):  <1x10-12*
Short term (Allan dev.):  <1 x 10-12 (t = 100s)
   <3 x 10-12 (t = 100s)
   <1 x 10-11(t = 10s)
   <3 x 10-11(t = 1s)
Warm up (+25°C):  20 mins to lock
  *At temperatures 23°C + 3°C
Frequency stability – Hold-over 910R 
(GPS-Rb)
Aging/24h:  <2 x 10-12 (typ.)
Aging/month:  <5 x 10-11
Temp. (0°C…+50°C):  <3 x 10-10
Temp. (23°C ± 3°C):  <2 x 10-11 (typ.)
Short term (Allan dev.):  <3 x 10-12 (t = 100s)
Frequency stability – Hold-over 910
(GPS-OCXO)
Aging/24h:  <3 x 10-10
Aging/month:  <3 x 10-9
Temp. (0°C…+50°C):  <2.5 x 10-9
Temp. (23°C ± 3°C):  <4 x 10-10 (typ.)
Short term (Allan dev.):  <1 x 10-11 (t = 100s)
   <5 x 10-12 ( t = 10s)
   <5 x 10-12 (t = 1s)
Warm up (+ 25°C):  10 minutes to 5 x 10-9
Phase Noise - 910R
Offset  Phase Noise
1 Hz:  -80 dBc/Hz (typ.)
10 Hz:  -90 dBc/Hz (typ.)
100 Hz:  -130 dBc/Hz (typ.)
1 KHz:  -140 dBc/Hz (typ.)
10 KHz:  -140 dBc/Hz (typ.)
100 KHz:  -145 dBc/Hz (typ.)
Phase Noise - 910
Offset  Phase Noise
1 Hz  -100 dBc/Hz (typ.)
10 Hz  -120 dBc/Hz (typ.)
100 Hz  -130 dBc/Hz (typ.)
1 KHz  -135 dBc/Hz (typ.)
10 KHz  -135 dBc/Hz (typ.)
100 KHz  -135 dBc/Hz (typ.)
Reference outputs (BNC)
10 MHz:  sine wave, 0.5V rms in 50O
5 MHz:  Sine wave, 0.5V rms in 50O
2.048 MHz (opt. 75):  +/-1.2V +/-10% in 75 ohms (G.703:10)
1 pps:  TTL-levels; low < 0.4V, high > 2V in 50O load
Pulse output (opt. 75):  TTL-levels; low < 0.4V, high > 2V in 50O load
5 additional 10 MHz outputs (option 70)
See specification for 10 MHz above
Multiple Reference outputs (option 71)
Sine wave outputs:  10, 5, 1 and 0.1 MHz >1 Vrms into 50 Ω
Pulse output:  0.1 MHz; >3 Vp-p into 50 Ω. 0 V =LO <0.8 V, 3 V
10 MHz and 5 MHz & 2.048 MHz (opt 72) outputs
Freq. Stability: See frequency stability specs for 910 and 910R
5 additional 13 MHz outputs (option 73)
Impedance:  50 Ω
Output signal:  TTL (symmetrical)
Typical levels into 50ƒn Ω  High voltage: 2.35 V
   Low voltage: 0 V
Risetime:  10 % - 90 %: 2 ns
Jitter:  < 0.01 UI
Long term stability:  Same as main reference
1-pps output (locked to GPS)
Duty Cycle:  Approx. 20%
Jitter:  <60 ns rms relative to UTC or GPS (position hold, SA on)
Pulse output 
(option 75)
The frequency is set via the included PC-program
Selectable frequency:  1/(N x 10-7) Hz, N is an integer
Factory default setting:  1 Hz
Duty cycle:  50%
Jitter:  <500 ps rms
Freq. Stability:  See frequency stability specs for 910 and 910R
Ethernet interface
(option 76)
Communication Port:  Connector: RJ45
   Protocol: 10Base-T
   Buffer RAM: 1 kbit
Configuration Port:  Connector: Dsub9, RS232
Internal data storage
24h-freq. Offset:  2 years data, non-volatile memory
Adjustment data:  2 years data, non-volatile memory
Controls
Manual 
Hold-over:
 Inhibits automatic GPS-adjustment and forces hold-over operation. This increases the short-term stability, when the internal Rubidium- or OCXO-reference is free running without any correction from the GPS-monitoring system.
LED Indicators - 
Locked to GPS
ON:  Disciplined mode
OFF:  Hold-over mode
LED Indicators -
Alarm
ON:  Alarm condition reported by instrument hardware. Explanatory text in 7-segment display area advises.
OFF:  Normal operation
LED Indicators - Manual Hold-over
ON:  Forced hold-over mode. If GPS signal is valid, the 24h frequency offset is displayed. Otherwise "-----" is shown.
OFF:  Automatic choice of disciplined or hold-over mode depending on "Locked to GPS" status.
GPS-receiver
Antenna connector:  Type N
Channels:  8, parallel tracking
Carrier, code:  L1, C/A
Antenna (option 01)
Type:  active L1
Operating temp.:  -40°C to +70°C
Height:  81 mm (3.2") (excl. connector)
Weight:  >30 dB
Gain:  TNC
Antenna cable
(option 02)
Type:  RG213
Length:  20 m
Connectors:  N-type and TNC (male)
Cable delay:  101 ns.
Attenuation:  Approx. 8 dB at 1.6 GHz
PC-connection
Interface:  RS-232, DTE
Connector:  9-pin male DB9, Rx on pin 2, Tx on pin 3, GND on pin 5
Baud rate:  9600 bps
Data structure:  8 data bits 1 stop bit, no parity
Fan
Temperature controlled
Environmental
Temperature:  0°C...+50°C (operating)
   -40°C...+70°C (storage)
Safety:  Compliant to CE: EN 61010-1 + A1 (1992) + A2 (1995)
EMI:  Compliant to CE: EN 1326-1 (1997)
Power consumption
Line voltage:  100...240 V (±10%)
Line frequency:  47..63 Hz
Power 910R:  <75 W at warm-up <35 W continuous operation
Power 910:  <25 W at warm-up <12 W continuous operation
Calibration Documentation Statement of calibration practices
Size
WxHxD:  315 x 86 x 395 mm
   12.4" x 3.4" x 15.6"
Weight

910R  4.4 kg net, 7.4 kg shipping (9.7 lb net, 16.3 lb shipping)
910  3.9 kg net, 6.9 kg shipping (8.6 lb net, 15.2 lb shipping)

Model Name Description
910

GPS Controlled OCXO Frequency Standard 5 x 10 MHz and 1 x 5 MHz outputs

All models include:

  • operator’s manual
  • statement of calibration practices

910R

GPS-Controlled Rubidium Frequency Standard.
5 x 10 MHz and 1 x 5 MHz outputs

Accessories common to all models:

Accessory Description
910-01

GPS Antenna

910-01/50

GPS Antenna Mounting Kit

910-50

Rack-Mount Kit

910-60

Carrying Case

910-70

5 additional 10 MHz outputs

910-71

Multiple reference outputs - 0.1 MHz, 1 MHz, 5 MHz and 10 MHz sinewave outputs, plus a 0.1 MHz squarewave output.

910-75

1 additional pulse output 0.5 Hz... 5 MHz

910-76

Ethernet interface

910R-01

GPS Antenna

910R-01/50

GPS Antenna Mounting Kit

910R-02/20

Antenna Cable, 20 m

910R-02/50

Antenna Cable, 50 m

910R-50

Rack-Mount Kit

910R-60

Carrying Case

910R-70

5 additional 10 MHz outputs

910R-71

Multiple reference outputs - 0.1 MHz, 1 MHz, 5 MHz and 10 MHz sinewave outputs, plus a 0.1 MHz squarewave output

910R-75

1 additional pulse output 0.5 Hz... 5 MHz

910R-76

Ethernet interface

Product Manuals
application/pdf icon 910 & 910R Operators Manual (1010.83 KB)
application/pdf icon 910 & 910R Operators Supplement (25.62 KB)
application/pdf icon 910 & 910R User Configuration Supplement (752.19 KB)
application/pdf icon 910/910R Statement of Memory Volatility (18.36 KB)
Data Sheets
application/pdf icon 910/910R GPS Controlled Frequency Standards Data Sheet (686.43 KB)
application/pdf icon 910/910R GPS制御周波数標準 データシート (992.19 KB)
application/pdf icon 910-910R GPS监控的频率参考基准 (873.69 KB)
Software
GPSView Software
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
    • Handheld Test Tools
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • "How To" Seminars
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Resource Centers
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Safety Data Sheets (SDS)
    • Safety, Service, and Product Notices
    • Software Downloads
    • Tools
      • PT100 Calculator
      • PT100 Table Generator
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
    • Why buy Fluke Calibration ?
Home|Products|Electrical Calibration|Electrical Standards|910/910R GPS Frequency Standards

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

Products

  • Product index
  • New products
  • Where to buy
  • Request a quote

Services

  • Calibration and repair
  • About Fluke Calibration
  • Service centers
  • Software downloads

Resources

  • Catalogs
  • Manuals
  • Web seminars
  • Subscribe to e-news
  • Supplier Handbook

Company

  • Contact us
  • About Fluke Calibration
  • Why choose us
  • Other Fluke companies
©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Terms of Use
  • Terms of Sale