• Other Fluke companies:
  • Fluke
  • Fluke Biomedical
  • Fluke Networks
  • Fluke Process Instruments
See more Fluke brands
Accelix Amprobe Beha-Amprobe Comark Emaint Landauer Pacific Laser Systems Pomona RaySafe Schad
Home
Precision, Performance, Confidence.
Fluke Calibration: US
  • Register
  • Log in
  • Contact Us

US - English [Change]

 

Get Quote

8558A 8.5 Digit Multimeter

8558A 8.5 Digit Multimeter, Front View
8558A 8.5 Digit Multimeter, Back View
8.5 Digit Multimeter in Factory
Fluke 8558A 8.5 Digit Multimeter in Rack in Factory
8558A 8.5 Digit Multimeter, Front View
8558A 8.5 Digit Multimeter, Back View
8.5 Digit Multimeter in Factory
Fluke 8558A 8.5 Digit Multimeter in Rack in Factory
Request a quote
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

The 8558A 8.5 digit multimeter offers 5 mega-samples-per-second high resolution digitizing for system automation in labs and manufacturing test environments.  Fluke’s new high-speed system design and the industry’s fastest direct digitizing capability enable significant throughput increases for many automated system applications that require a combination of highest speed and best accuracy.  The superb accuracy is delivered over a wide measurement range, over nine functions, with an intuitive user interface on a color display.

The 8558A shares the same platform as the fully loaded 8588A Reference Multimeter. The platform features a common intuitive user interface with easy-to-navigate menu structure for all configuration and matching SCPI-compliant commands for automated environment. The 8588A platform guarantees a minimum of 100,000 readings per second at 4.5 digits across GPIB, USBTMC or Ethernet, and an onboard data memory that can hold up to 15 million readings.

8558A feature callouts

Fluke 8558A with callouts (Front)

A. Visual Connection Management terminals
Active terminals light up, guiding the user to make the correct connections.

B. Easy-to-access configurations
Range, aperture, input impedance, RMS filter and other measurement configurations are readily available.

C. Large, bright full color display
The intuitive user interface and flat menu structure make it easy to access configurations and view trend plots, waveforms, FFT, histogram and statistics.

D. Programmable front/rear electronic switch
Eliminates manual operation and allows immediate ratio results through a single remote command.

E. 30 A terminal (8588A only; 2A for 8558A)
Enables industry's widest current measurement range through a single terminal.

F. Soft menu keys
Adapt to the active function, so the menu structure is intuitive and easy to learn.

G. Multi-language selection
Choice of English, Chinese, French, Japanese, Korean, Russian and Spanish.

H. Run/Stop trigger
Toggles the continuous, or free run, measurement state.

I. USB ports
Download data quickly and easily to a flash drive.

Fluke 8558A with callouts (Back)
J. Trig in/Trig out
Precise triggering maximizes synchronization in system automation.

K. Freq Counter
Enables 100 MHz frequency counter measurement at 0.5 uHz/z.

L. Rear panel input terminals
Mirrors front panel input terminals for connection compatibility and allows for front/rear scan measurement.

M. IEEE 488, LAN, USB interfaces
Standard remote interface for straightforward system integration.

N. USB port
Download data quickly and easily to a flash drive.

O. 2 A terminal

8558A key features and performance

DC voltage
  • 100 mV to 1000 V, (1050V max)
  • 2.02x full scale
  • Maximum resolution: 1 nV
  • 4.0 μV/V (95 %) 5.7 μV/V (99 %), 1 year
  • 0.5 μV/V (95 %) 0.65 μV/V (99 %), 24 hour stability
  • 0 to 10 s reading aperture (200 ns resolution)
     
DC current
  • 10 uA to 2 A (8558A)
  • 2.02x full scale
  • Maximum resolution: 1 pA
  • 9 μA/A (95 %), 12 μA/V (99 %), 1 year
  • 0 ns to 100 s reading aperture
 
AC voltage
  • 10 mV to 1000 V, 1 Hz to 10 MHz, (1050 Vrms max)
  • 2.02x full scale Vpp, 1.2x full scale Vrms
  • Maximum resolution: 1 nV
  • 80 μV/V (95 %), 103 μV/V (99 %), 1 year
 
AC current
  • 10 uA to 30 A (8588A only; 2 A for 8558A)
  • 2.02x full scale Vpp, 1 Hz to 100 kHz 1.2x full scale Vrms
  • Maximum resolution: 1 pA
  • 300 μA/A (95 %), 387 μA/V (99 %), 1 year
 
Resistance
  • 1Ω to 10 GΩ (20 GΩ max)
  • 2.02x full scale
  • Maximum resolution: 10 nΩ
  • 10 μΩ/Ω (95 %), 13 μΩ/Ω (99 %), 1 year
  • Low current mode, high voltage mode and current-reversal Tru Ohms™
 
Digitize V
  • 100 mV to 1000 V, (1050 V max)
  • 2.02x full scale
  • Maximum resolution: 18 bits
  • 5 mega-samples per second sample rate
  • Up to 20 MHz bandwidth
     
Digitize I
  • 10 μA to 30 A (8588A only; 2 A for 8558A)
  • 2.02x full scale
  • Maximum resolution: 18 bits
  • 5 mega-samples per second sample rate
  • Up to 4 MHz bandwidth
     
Frequency or period
  • Voltage, up to 10 MHz
  • Current, up to 100 kHz
  • Frequency up to 100 MHz on BNC
  • 0.5 μHz/Hz, 1 year
     
Capacitance
  • 1 nF to 100 mF
  • 400 μF/F, 1 year
     
Temperature
  • PRT and thermocouple
  • 5 mK PRT, 25 mK TC - 1 year
     
RF power
  • Rhode & Schwarz NRP series DC I and AC I external shunt

DC I and AC I external shunt

  • A40B and any other external shunt
 
Reading speed
  • 1 reading /s @ 8.5 digit into memory
  • 100,000 readings /s @ 4.5 digit into memory
  • Up to 5,000,000 (5 MS/s) readings /s into volatile memory in digitize V and I
  • Up to 500,000 readings/s transfer through USB in binary format
 
Measurement memory
  • 15 million readings volitile
  • 7.5 million readings with volitile time stamp
  • 16 GB non-volitile
 
GPIB, USBTMC, Ethernet
  • Native SCPI compliant remote commands
  • 8508A and 3458A emulation mode
  • Fully support MET/CAL™ calibration procedures library in Fluke 8508A emulation
  • IVI driver
  • USB thumb drive for convenient data transfer in .csv format
 
Trigger mechanisms
  • Manual trigger
  • External BNC Trig In and Trig Out
  • Internal or level trigger
  • Timer trigger
  • Epoch trigger
  • Line trigger
  • BUS trigger
     
CE and CSA compliant

Looking for lower resolution?

See our 6.5 digit and 5.5 digit multimeters. See the full lineup of Fluke bench multimeters.

Accurate data, delivered amazingly fast

Shorter test time on the 8588A/8558A high-speed digital platform enables you to increase throughput, improve yield and realize a greater return on your investment. The 8588A/8558A digitizes to memory at 200 nanoseconds per reading and delivers 4.5 digit data to a PC via USB, Ethernet and GPIB at 100,000 readings per second. Fast, high resolution data capture gives you the quantity and quality of information you need to make timely, correct decisions affecting system throughput and efficiency.

  • 0 ns to 100 s aperture setting allows industry’s widest flexibility to control data capture window
  • Reading speed: 1 reading /s @ 8.5 digits to 100,000 reading /s @ 4.5 digits
  • Data transfer from memory to PC: up to 500,000 readings /s in binary format through USB, up to 200,000 through Ethernet and GPIB

Debug and perfect your device under test

The 8558A features a 5 mega-sample digitizing rate with up to 20 MHz analog bandwidth, making it the first and only instrument on the market that can characterize extremely low level transient signals at 18-bit resolution. This capability makes it easier to debug designs, uncover anomalies and perfect your devices under test for use in real life environments.

  • Voltage sensitivity to hundreds of nV and current sensitivity to hundreds of pA allows you uncover ultra-low level transient signals
  • Up to 20 MHz bandwidth for voltage and 4 MHz for current retains high bandwidth content of the signal measured
  • 18-bit SAR analog-to-digital converter that achieves 5 mega-samples per second
  • 5 mega-samples per second sample rate, into buffer, for capturing complex, fast changing waveforms
  • 15 million readings memory allows large amount of data storage eliminating the
  • immediate need to transfer data to a PC
  • Graphical waveform display enables real-time visualization of complex waveforms, increased productivity with faster access to results and answers

Fast, reliable and accurate system compatibility

Inserting a new instrument into a tightly synchronized system can create overhead and incompatibility. The 8558A’s digital platform includes common connectivity interfaces plus precise triggering that lets it digitize, integrate and transfer data to anywhere in the system for analysis, with minimal obstruction and the highest reliability.

  • GPIB, USBTMC, Ethernet allows industry standard selection of remote interface
  • USB thumb drive enable quick and easy data transfer to PC in .csv format
  • SCPI compliant commands with 8505A and 3458A emulation mode simplifies and accelerates system upgrade process to 8588A/8558A
  • Fully supports MET/CAL calibration procedures library that commands the Fluke 8508A 
  • IVI Driver for industry standard control of DMM on 8558A/8588A
  • Trigger Mechanisms: External BNC Trigger Trig In and Trig Out, Edge or level trigger, Timer trigger, Epoch trigger, Line trigger
  • Less than 100 ns trigger latency with external BNC trigger for digitize voltage and current

8558A Analyze: FFT, screen capture

Analyze: FFT

8558A Trend Plot, screen capture

Trend Plot

8558A Trigger System, screen capture

Trigger System

Usability features ease training and operation

Some popular system digit multimeters have complex menu structures and unintuitive commands, while others lack any user interface, presenting barriers to training and operation. By contrast, the 8558A features an easy-to-access configuration menu that makes it easy to train new users. Language choices include English, Chinese, French, German, Japanese, Korean, Russian and Spanish. The graphical display lets you easily visualize trends, histograms, complex waveforms, and statistics. Repeatable system-specific tasks can be automated quickly and easily.

The 8558A’s front panel features Visual Connection Management™ output terminals that light up to show which terminals are active, guiding the user to make the correct connections. The handles and spin wheel are over-molded for comfort and easy transport.

USB host ports are placed both on the front and rear of the unit. Use them to export data to external memory devices and simplify firmware updates.

8558A Trend Plot, screen capture

Trend Plot

8558A Analyze: Histogram, screen capture

Analyze: Histogram

The MET/CAL™ Calibration Management Software advantage

The 8588A and 8558A work with Fluke Calibration MET/CAL™ Calibration Software with native MET/CAL support or using 8508A emulation mode to increase throughput up to four times that of traditional manual and multi-product methods while ensuring calibrations are performed consistently every time. This powerful software documents calibration procedures, processes and results for ease in complying with ISO 17025 and similar quality standards.

Support and services when you need them

Fluke Calibration offers testing, repair and calibration services to meet your needs quickly and at a fair cost while maintaining the high level of quality that you expect. Our electrical calibration laboratories are accredited for conformance to ISO/IEC Guide 17025 and we maintain global calibration and repair facilities.

Get peace of mind and uptime with a Gold CarePlan service package

The 8588A/8558A multimeters come with a standard one year factory warranty. You can enhance warranty protection with a Priority Gold Instrument CarePlan service package.

A Priority Gold Instrument CarePlan includes an expedited annual calibration to reduce downtime by a week and extended warranty to help ensure the best long-term performance from your instruments. Choose from one-year, three-year or five-year Care- Plans. (Note: Priority shipping times vary by country. Contact your local Fluke Calibration sales representative for details.)

8588A complete specifications

8558A complete specifications

Key feature and specification comparison

  8558A 8588A
DC voltage 100 mV – 1000 V 100 mV – 1000 V
AC voltage 10 mV – 1000 V, 1 Hz – 10 MHz 10 mV – 1000 V, 1 Hz – 10 MHz
Resistance, LoI, HV 1 Ω - 10 GΩ 1 Ω - 10 GΩ
DC current 10 uA – 2 A 10 uA – 30 A
AC current 10 uA – 2A, 1 Hz to 100 kHz 10 uA – 30 A, 1 Hz to 100 kHz
Digitize V 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW
Digitize I
10 uA - 2 A, 5 MSamples/s,
up to 4 MHz BW
10 uA - 30 A, 5 MSamples/s, up to 4 MHz BW
Frequency (V, I, BNC) 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz
Temperature PRT / Thermocouple (ext CJC) PRT / Thermocouple (ext CJC)
Capacitance No 1 nF – 100 mF
RF power No R&S NRP Series
Ext. dc current and ac current No A40B current shunt and other shunts
Graphical display Yes Yes
Visual Connection Management ® Yes Yes
Programmable front/rear input switching Yes Yes
Ratio difference, deviation - ohms, voltage Yes Yes
External 10 MHz ref clock, 50 Ω/Hi-Z Yes Yes
A40B and other shunt asset management No Yes
GPIB 488.2, Ethernet, USB TMC Yes Yes
SCPI command compatibility Yes Yes
3458A emulation, 8508A emulation Yes Yes
Memory 15 million 15 million
Level and other trigger Yes Yes
FFT onboard No Yes
Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digits Yes Yes

 

Function     8558A uX/X of reading + uX/X of range  8588A uX/X of reading + uX/X of range 
      95% 99% 95% 99%
DC voltage 10 V relative 4.0 + 0.06 5.2 + 0.08 2.7 + 0.05 3.5 + 0.06
absolute 4.1 + 0.06 5.3 + 0.08 2.8 + 0.05 3.6 + 0.06
AC voltage 10 V, 1 kHz relative 80 + 10 103 + 13 60 + 5 77 + 6.5
absolute 90 + 10 116 + 13 64 + 5 83 + 6.5
Resistance 10 kΩ relative 10 + 0.6 13 + 0.7 7 + 0.5 9 + 0.6
absolute 10.3 + 0.6 13.3 + 0.7 7.2 + 0.5 9.2 + 0.6
DC current 1 mA relative 9 + 5 12 + 6 6.5 + 4 8.4 + 5
absolute 9.8 + 5 13 + 6 7.6 + 4 10 + 5
AC current 1 mA, 1 kHz relative 300 + 100 387 + 129 250 + 50 323 + 65
absolute 310 + 100 400 + 129 260 + 50 335 + 65
Frequency 1 kHz relative N/A N/A 0.5 0.5
Temperature PRT 100 Ω relative ± 5 mK ± 5 mK ± 5 mK ± 5 mK
Capacitance 1 uF relative N/A N/A 400 + 100 516 + 129
absolute N/A N/A 406 + 100 523 + 129

95% 1 year relative specification. Fluke Calibration guarantees to 99% confidence interval k=2.58. For 99%, multiply by (2.58/2)

Looking for lower specs? See our other benchtop multimeters:

Bench Multimeter Selection Guide
Model Resolution Accuracy Application
8588A 8.5 2.7 µV/V 95% confidence level, 1 year relative accuracy Metrology
8558A 8.5 4.0 µV/V 95% confidence level, 1 year relative accuracy High-Speed Automation
8845A/8846A 6.5 Basic V dc accuracy of up to 0.0024 % Bench
8808A 5.5 Basic V dc accuracy of 0.015 % Bench

Model Name Description
8558A

8.5 Digit Multimeter

Includes:

  • Meter
  • 8588A-LEAD KIT-OSP General purpose probe kit & pouch with 2x 4-way shorting PCB
8588A

Reference Multimeter

Includes:

  • Meter
  • 8588A-LEAD KIT-OSP General purpose probe kit & pouch with 2x 4-way shorting PCB

Accessories common to all models:

Accessory Description
Y8588

Rack Mount Kit (2U – 3.5 in)

Y8588S

Slide Rack Mount Kit

8588A-LEAD

Comprehensive Measurement Lead Kit
Includes:

  • 1x 8588A-LEAD KIT-OSP
  • 1x 1 m screen 322/0.1 copper (30 Amp Rating) with 6 mm gold plated copper spade terminals
  • 4X 8588A-LEAD/THERMAL
  • 2x locking adapter 4 mm binding post to safety
8588A-SHORT

4-Way Shorting PCB

8588A-LEAD/THERMAL

Low Thermal Lead Kit

8588A-7000K

Cal Kit with 1 Gohm Standard and Connecting Leads

96000SNS

Additional Power Sensor 

8588A/CASE

Transit Case

Product Manuals
application/pdf icon 8588A/8558A Operators (1.75 MB)
application/pdf icon 8588A/8558A Operators (fre) (1.75 MB)
application/pdf icon 8588A/8558A Operators (ger) (1.79 MB)
application/pdf icon 8588A/8558A Operators (jpn) (1.93 MB)
application/pdf icon 8588A/8558A Operators (kor) (1.87 MB)
application/pdf icon 8588A/8558A Operators (rus) (1.8 MB)
application/pdf icon 8588A/8558A Operators (spa) (1.72 MB)
application/pdf icon 8588A/8558A Operators (chi) (1.96 MB)
application/pdf icon 8588A/8558A Remote Programmers (601.2 KB)
application/pdf icon 8588A/8558A Remote Programmers Supplement (183.71 KB)
application/pdf icon 8588A/8558A Safety Information (260.68 KB)
application/pdf icon 8588A/8558A Safety Information (chi) (470.82 KB)
application/pdf icon 8588A/8558A Safety Information (fre) (274.96 KB)
application/pdf icon 8588A/8558A Safety Information (ger) (281.9 KB)
application/pdf icon 8588A/8558A Safety Information (jpn) (364.12 KB)
application/pdf icon 8588A/8558A Safety Information (kor) (384.09 KB)
application/pdf icon 8588A/8558A Safety Information (rus) (312.94 KB)
application/pdf icon 8588A/8558A Safety Information (spa) (276.81 KB)
application/pdf icon 8588A/8558A Service (1.73 MB)
application/pdf icon 8588A/8558A Statement of Memory Volatility (73.86 KB)
Application Notes
application/pdf icon Improved verification of a 55XX Series Multi-Product Calibrator with an 8588A Reference Multimeter (428.74 KB)
application/pdf icon Inside the newest 8.5 digit Reference Multimeter (4.92 MB)
application/pdf icon Overview of 8588A and 8558A calibration support processes and equipment requirements (382.12 KB)
application/pdf icon Verifying the capacitance function of the 8588A Reference Multimeter (1.21 MB)
application/pdf icon Replacing analog null detectors with precision multimeters (1.87 MB)
Brochures
application/pdf icon 8588A Reference Multimeter / 8558A 8.5-Digit Multimeter Brochure (2.36 MB)
application/pdf icon Referenzmultimeter 8588A 8,5-stelliges Multimeter 8558A (1.99 MB)
application/pdf icon Multímetro de referencia 8588A Multímetro de 8,5 dígitos 8558A (1.98 MB)
application/pdf icon Multimètre de référence 8588A Multimètre à 8,5 chiffres 8558A (1.98 MB)
application/pdf icon 8588A 레퍼런스 멀티미터 8558A 8.5 디지트 멀티미터 (2.08 MB)
application/pdf icon Эталонный мультиметр 8588A 8,5-разрядный мультиметр 8558A (2.11 MB)
application/pdf icon 8588A リファレンス・マルチメーター 8558A 8.5 デジタル・マルチメーター (21.96 MB)
application/pdf icon Multímetro de referência 8588A Multímetro de 8,5 dígitos 8558A (1.98 MB)
Firmware
8588A & 8558A Firmware, Update by USB
Papers / Articles
The best benchtop multimeter - an open letter from Roger Peniche, Director of Engineering at Fluke Calibration
application/pdf icon Fluke 8588A Reference Multimeter Evaluation (5.65 MB)
Specifications
application/pdf icon 8558A Product Specifications (459.78 KB)
Video
8588A Reference Multimeter Introduction Video
Choosing a Digital Bench Multimeter
Fluke 8588A Reference Multimeter Demo Video
White Paper
Using precision digital multimeters in place of analog null meters for metrological applications
Press Releases
Fluke Calibration launches the world’s most stable digitizing multimeter
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
    • Handheld Test Tools
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • "How To" Seminars
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Resource Centers
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Safety Data Sheets (SDS)
    • Safety, Service, and Product Notices
    • Software Downloads
    • Tools
      • PT100 Calculator
      • PT100 Table Generator
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
    • Why buy Fluke Calibration ?
Home|Products|Electrical Calibration|Bench Multimeters|8558A 8.5 Digit Multimeter

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

Products

  • Product index
  • New products
  • Where to buy
  • Request a quote

Services

  • Calibration and repair
  • About Fluke Calibration
  • Service centers
  • Software downloads

Resources

  • Catalogs
  • Manuals
  • Web seminars
  • Subscribe to e-news
  • Supplier Handbook

Company

  • Contact us
  • About Fluke Calibration
  • Why choose us
  • Other Fluke companies
©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Terms of Use
  • Terms of Sale