• Other Fluke companies:
  • Fluke
  • Fluke Biomedical
  • Fluke Networks
  • Fluke Process Instruments
See more Fluke brands
Accelix Amprobe Beha-Amprobe Comark Emaint Landauer Pacific Laser Systems Pomona RaySafe Schad
Home
Precision, Performance, Confidence.
Fluke Calibration: US
  • Register
  • Log in
  • Contact Us

US - English [Change]

 

RPM3 v1.02j Embedded Software

TITLE VER USE WITH
RPM3™ 1.02j
2005.06.27
RPM3
TITLE VER USE WITH
RPM3™ 1.02j
2005.06.27
RPM3
Instructions:
Do Not use with HGC-30000-AF!

Download the file.

Run Winflash and select the file downloaded as the file to write to the product.

Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.

If your product has an model number ending in "-AF", it requires specific "-AF" embedded software.

The updating of embedded software should only be performed after given specific instructions to do so from a Fluke Calibration Authorized Service Center ».

If the update isn't performed properly, your product will be inoperable until it is.

Updates Include:
Rev 1.02j (2005 Jun 27)
FIX: When RS232 test is run, COM2 to COM1 no longer always fails.

Rev 1.02i (2003 May 16)
CHG: Display mode (e.g. Rate, Average, Freeze) is retained when power is removed from the unit.

Rev 1.02h (2002 Sep 20)
FIX: remove 'a' and 'g' reference characters from the pressure unit when the unit is 'ft' or 'm'.

Rev 1.02g (2001 Dec 17)
CHG: A0015 RPT range H3 to 16 psia/0psig in US version and 110 kPaa/0 kPag in SI version.
FIX: Operation of local "Device Clear" GPIB command.
FIX: "INIT:CONT?" command query now replies.
FIX: GPIB bus would hang if a single char was sent as a command.

Rev 1.02e (2001 Feb 26)
FIX: Older style RPTs without temperature compensation now read at normal internal (1.2 sec at idle) instead of 3.2 sec.

Rev 1.02d (2001 Jan 10)
Factory level changes only relating to G0002 RPTs in SI units.

Rev 1.02c (2001 Jan 02)
FIX: Upper & lower limit for the zero warning on an abs RPT to include worst case RPT error.

Rev 1.02a (1998 Dec 29)
ADD: the new command "SYSTEM:RANGES?" that replies the defined ranges for the RPT(s) in gauge and absolute modes.
ADD: New command "DISP:RPT?" that replies the actively displayed RPT channel number and range.
FIX: incorrect error reply if the TIME remote command arg is invalid.
FIX: The Head Fluid/Liquid menu selection would select the incorrect type. Selecting "oil" actually selected "H2O", "H2O" selected "User" & "User selected "H2O".
FIX: Restructure data to prevent a RESET ALL from occurring when upgraded future versions. This should be the last ver requiring a RESET ALL as part of the upgrade. RESETS: This rev will execute a "RESET ALL", setting all USER settings and Calibrations to defaults.
FIX: COM1 compound reply that included "OK" is missing the seperator ';' between "OK" and the next reply ("OKOKOK" instead of "OK;OK;OK").
FIX: Correct the clock date entry fields to correct for leap years. (YYYY02DD where DD limited to 28/29 instead of just 29).
FIX: The leak check period entered when leak checking would not be saved for the next leak check, and a 15s period would be used to calc the leak rate instead of the entered value.

Rev 1.02
Expand res of factory baic barometer cal fields.
ADD: PPT diag menu select to help diag PPT communications errors.
ADD: Diag disp screen to disp the Baro vs RPT pressure ("AmbChk")
ADD: A2d cfg menu in DIAG menu so chgs can be made to the A2d sys config.
ADD: Reset the COM port settings if a memory failure causes a reset ALL.
FIX: Possible IEEE initialization error. Would cause FATAL EXCEPTIONS.
FIX: Diag COM test to work with COM5,6,7. Used to give INVALID indication.
FIX: DIAG:PRES:AMB:COUNTS? query.
FIX: Possible problem in parsing common commands ("*XXX") due to a length of command table being used incorrectly.
FIX: Change "G0002b" MID range from 15.2 to 16.2 psi.
FIX: Use of ZOFFSET when cal the final pressure on a gauge RPT is not determined by the tare eneable/disable, but is randomly determined meas to meas.

Revision #: 
1.02j
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Function and Waveform Generators
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
        • Custom Baths
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
    • Handheld Test Tools
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • "How To" Seminars
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Resource Centers
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Register Products
    • Safety Data Sheets (SDS)
    • Safety, Service, and Product Notices
    • Software Downloads
    • Tools
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
    • Why buy Fluke Calibration ?
Home|Literature|Software Downloads|Firmware|RPM3 v1.02j Embedded Software

We'd like your feedback.

You can help us improve our website »

Thank you!

If you purchased an item from a Fluke authorized distributor, please contact them directly with questions regarding Certificates of Calibration or other documentation.

Support requests for items purchased from, or serviced directly by Fluke and general Metrology questions can be submitted via our online Support Request form and a Fluke representative will be in contact with you.

©1995-2021 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Webmaster
  • Terms of Use
  • Terms of Sale