Improved specifications enable high performance workload calibration

Sourcing ac voltage, ac current, and resistance can be a problem when calibrating some 8.5-digit digital multimeters, like the Fluke 8508A and Agilent 3458A. The 5730A delivers improved performance for these specifications.

  5700A 5720A 5730A
DC voltage range 0 to ± 1100 V 0 to ± 1100 V 0 to ± 1100 V
Best 1 year, 95 % specification 7 ppm + 3.5 μV 3.5 ppm + 2.5 μV 3.5 ppm + 2.5 μV
AC voltage range 220 mV to 1100 V
10 Hz to 1 MHz
220 mV to 1100 V
10 Hz to 1 MHz
220 mV to 1100 V
10 Hz to 1 MHz
Best 1 year, 95 % specification 75 ppm + 6 μV 45 ppm + 8 μV 42 ppm + 8 μV
DC current range 0 to ± 2.2 A
5725A: 0 to ± 11 A
0 to ± 2.2 A
5725A: 0 to ± 11 A
0 to ± 2.2 A
5725A: 0 to ± 11 A
52120A: 0 to ± 100 A
Best 1 year, 95 % specification 50 ppm + 8 nA 35 ppm + 7 nA 35 ppm + 7 nA
AC current range 9 μA to 2.2 A,
10 Hz to 10 kHz

5725A: 9 μA to 11 A
9 μA to 2.2 A,
10 Hz to 10 kHz

5725A: 9 μA to 11 A
9 μA to 2.2 A,
10 Hz to 10 kHz

5725A: 9 μA to 11 A
52120A: 9 μA to 120 A
Best 1 year, 95 % specification 140 ppm + 16 nA 120 ppm + 8 nA 103 ppm + 8 nA
Resistance range 0 to 100 MΩ,
18 values in x1 and x1.9
0 to 100 MΩ,
18 values in x1 and x1.9
0 to 100 MΩ,
18 values in x1 and x1.9
Best 1 year, 95 % specification 12 ppm 8.5 ppm 6.5 ppm
Wideband option range 300 μV to 3.5 V,
10 Hz to 30 MHz
300 μV to 3.5 V,
10 Hz to 30 MHz
300 μV to 3.5 V,
10 Hz to 50 MHz
Best 1 year, 95 % specification ± 0.4 % of setting ± 0.4 % of setting ± 0.4 % of setting
6.5-Inch full color capacative
2

Simplify setup with the 6.5-inch full color capacitive touch screen display

  • Navigating menus is a snap
  • Bright and legible
Visual Connection Management
3

Visual Connection Management output terminals help operators make the correct connections

  • Terminals light up to indicate where cables should be plugged in for each function
Connect the Fluke Calibration 52120A or 5725A Amplifiers
4

Expand the calibration workload to high current instruments by connecting the Fluke Calibration 52120A or 5725A Amplifiers

  • Extend the current range of the 5370A to calibrate workload up to 11 A (5725A) or 120 A (52120A)
  • Calibrate current clamps and coils up to 6,000A with the addition of the 52120A/Coil
Automate with MET/CAL Calibration Management Software
5

Automate with MET/CAL® Calibration Management Software

  • Save time and money
  • Eliminate errors
  • Perform controlled, consistent tests
  • Comply with standards
  • Improve productivity
50 MHz wideband option
6

50 MHz wideband option enables calibration of the 5790B AC Measurement Standard's 50 MHz input

6.5-Inch full color capacative
7

Choice of languages

English, French, German, Spanish, Japanese, Chinese, Portuguese, Russian, and Korean

USB bus and ethernet port
8

Control the 5730A remotely with a PC over the USB bus or Ethernet port

Redesigned PCAs
9

Redesigned PCAs offer better support for the future

Newer digital components and technology offer better support for the future.

10
Product list

Limited-time offer:

Trade in your old 5700A or 5720A Multifunction Calibrator and get a new 5730A High Performance Multifunction Calibrator at 20% savings. Read the complete terms and conditions of this Program.

Contact us to get a free quote.