4180/4181 Precision Infrared Calibrators

4180/4181 Precision Infrared Calibrators
4180/4181 Precision Infrared Calibrators

Accuracy and traceability for infrared measurements

Now it’s easy to increase your IR temperature measurement accuracy with the new 4180/81 Precision Infrared Calibrators from Fluke Calibration. These infrared temperature calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimizes size of source effect errors. In addition, these infrared calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.

New accredited performance for point-and-shoot calibrations

  • Calibrated radiometrically for meaningful, consistent results.
  • Accredited calibration included
  • Accurate, reliable performance from –15 °C to 500 °C
  • Large target size of 152 mm (6 in) is required for calibrating most thermometers.
  • Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
  • Intuitive, easy-to-read display that indicates when temperature is stable.

 

The 4180 Series of Precision InfraredCalibrators for infrared thermometers and thermal imagers is fast, accurate, and easy to use. It comes with an accredited calibration from one of the world’s most trusted temperature calibration laboratories, sample calibration procedures for Fluke thermometers built right in and everything you need to get started making high-quality infrared thermometer calibrations. This is the perfect solution for any infrared thermometer or thermal imager within its temperature range.

The 4180 Infrared Temperature Calibrator reaches temperatures from –15 °C to 120 °C and the 4181 Infrared Temperature Calibrator has a temperature range from 35 °C to 500 °C. Uniformity is important in infrared temperature calibration work because an infrared thermometer will “see” as much as the entire target when placed at the appropriate calibration distance.

In addition, with accuracies as good as ± 0.35 °C the 4180 Series can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.

Emissivity, blackbodies and graybodies
Most people associate a blackbody calibration source with calibrating infrared thermometers. Although the word blackbody specifically refers to an ideal surface that emits and absorbs electromagnetic radiation with the maximum amount of power possible at a given temperature, many calibrators with non-ideal surfaces are also referred to as "blackbody calibrators." While an ideal surface would have an emissivity equal to 1.00, many of these "blackbody calibrators" have an emissivity of approximately 0.95 (better described as a “graybody”). A true blackbody calibration source would usually be a long cavity with a narrow opening. Unfortunately the opening is usually too narrow to be useful for calibrating common infrared thermometers which require a large target size for an accurate calibration. The advantage of a true blackbody calibration source is that the emissivity is precisely known. Whereas traditional flat plate calibrators have emissivities with uncertainties too large for meaningful calibrations of most thermometers. That is why the 418X Precision Infrared Thermometers are radiometrically calibrated to correct for uncertainties caused by emissivity and heat loss at the surface of the "blackbody" calibration source.
 

Specifications
Temperature range (@ 23 °C ambient, 0.95 emissivity)
4180  –15 °C to 120 °C
4181  35 °C to 500 °C
Display accuracy1
4180  ± 0.40 °C at –15 °C
   ± 0.40 °C at 0 °C
   ± 0.50 °C at 50 °C
   ± 0.50 °C at 100 °C
   ± 0.55 °C at 120 °C
4181  ± 0.35 °C at 35 °C
   ± 0.50 °C at 100 °C
   ± 0.70 °C at 200 °C
   ± 1.20 °C at 350 °C
   ± 1.60 °C at 500 °C
Stability
4180  ± 0.10 °C at –15 °C
   ± 0.05 °C at 0 °C
   ± 0.10 °C at 120 °C
4181  ± 0.05 °C at 35 °C
   ± 0.20 °C at 200 °C
   ± 0.40 °C at 500 °C
Uniformity (5.0 in dia of center of target)2
4180  ± 0.15 °C at –15 °C
   ± 0.10 °C at 0 °C
   ± 0.25 °C at 120 °C
4181  ± 0.10 °C at 35 °C
   ± 0.50 °C at 250 °C
   ± 1.00 °C at 500 °C
Uniformity (2.0 in dia of center of target)2
4180  ± 0.10 °C at -15 °C
   ± 0.10 °C at 0 °C
   ± 0.20 °C at 120 °C
4181  ± 0.10 °C at 35 °C
   ± 0.25 °C at 250 °C
   ± 0.50 °C at 500 °C
Heating time
4180  15 min: –15 °C to 120 °C
   14 min: 23 °C to 120 °C
4181  20 min: 35 °C to 500 °C
Cooling time
4180  15 min: 120 °C to 23 °C
   20 min: 23 °C to –15 °C
4181  100 min: 500 °C to 35 °C
   40 min: 500 °C to 100 °C
Stabilization time
   10 minutes
Nominal emissivity3
   0.95
Thermometer emissivity compensation
   0.9 to 1.0
Target diameter
   152.4 mm (6 in)
Computer interface
   RS-232
Power
4180  115 V ac (± 10%), 6.3 A,
   50/60 Hz, 630 W
   230 V ac (± 10%), 3.15 A,
   50/60 Hz, 630 W
4181  115 V ac (± 10%), 10 A,
   50/60 Hz, 1000 W
   230 V ac (± 10%), 5 A,
   50/60 Hz, 1000 W
Fuse(s)
4180  115 V ac 6.3 A, 250 V, slow blow
   230 V ac 3.15 A, 250 V, T
4181  115 V ac 10 A, 250 V, fast blow
   230 V ac 5 A, 250 V, F
Size (HxWxD)
4180  356 mm x 241 mm x 216 mm
   (14 in x 9.5 in x 8.5 in)
4181  356 mm x 241 mm x 216 mm
   (14 in x 9.5 in x 8.5 in)
Weight
4180  9.1 kg (20 lb)
4181  9.5 kg (21 lb)
Safety
   EN 61010-1:2001, CAN/CSA C22.2 No.
   61010.1-04

1For 8 µm to 14 µm spectral band thermometers with emissivity set between 0.9 and 1.0

2The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the targer will measure the same temperature.

3The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties.

Model Name Description
4180

IR Calibrator, 152 mm (6 in), –15 °C to 120 °C
Includes:

  • 4180 IR Calibrator
  • Report of Calibration (NVLAP Accredited)
  • Power Cord
  • User’s Guide
  • Documentation CD
  • Target Cover
  • Serial Cable

 

4181

IR Calibrator, 152 mm (6 in), 35 °C to 500 °C
Includes:

  • 4181 IR Calibrator
  • Report of Calibration (NVLAP Accredited)
  • Power Cord
  • User’s Guide
  • Documentation CD
  • Target Cover
  • Serial Cable

Accessories common to all models:

Accessory Description
4180-APRT

Aperture, 50 mm (2 in), 4180 or 4181

4180-CASE

Case, Carrying, 4180/4181

4180-DCAS

Case, 4180-81, Carrying, w/Wheels

SC1-RDIR

Silver Care Plan, 1-yr Extended Warranty, Radiometric IR Calibrators

SC2-RDIR

Silver Care Plan, 2-yr Extended Warranty, Radiometric IR Calibrators

SC4-RDIR

Silver Care Plan, 4-yr Extended Warranty, Radiometric IR Calibrators

Product Manuals
application/pdf icon4180/4181 Technical Guide (1.88 MB)
application/pdf icon4180/4181 Precision Infrared Calibrator Users Guide (English) (1.32 MB)
application/pdf icon4180/4181 Precision Infrared Calibrator Users Guide (Chinese) (1.9 MB)
application/pdf icon4180/4181 Precision Infrared Calibrator Users Guide (Spanish) (1.58 MB)
application/pdf icon4180/4181 Precision Infrared Calibrator Users Guide (German) (1.58 MB)
application/pdf icon4180/4181 Precision Infrared Calibrator Users Guide (Japanese) (1.22 MB)
application/pdf icon4180/4181 Precision Infrared Calibrator Users Guide (Italian) (1.57 MB)
application/pdf icon4180/4181 Precision Infrared Calibrator Users Guide (French) (1.56 MB)
application/pdf icon4180/4181 Precision Infrared Calibrator Users Guide (Russian) (1.2 MB)
application/pdf icon4180/4181 Statement of Memory Volatility (16.4 KB)
Brochures
application/pdf icon4180 Series Precision Infrared Calibrators Brochure (English) (1.23 MB)
application/pdf iconPräzisions-Infrarot Kalibratoren der Serie 4180 Brochure (German) (811.32 KB)
application/pdf iconCalibrateurs infrarouges de précision série 4180 Brochure (French) (809.47 KB)
application/pdf iconCalibradores por infrarrojos de precisión de la serie 4180 Brochure (Spanish) (806.61 KB)
application/pdf iconПрецизионные инфракрасные калибраторы серии 4180 Brochure (Russian) (898.66 KB)
application/pdf iconCalibratori ad infrarossi di precisone Serie 4180 Brochure (Italian) (805.6 KB)
application/pdf icon4180 Series Precision Infrared Calibrators Flyer (305.48 KB)
application/pdf icon4180シリーズ 放射温度計校正器カタログ (992.83 KB)
application/pdf iconIndustrial Temperature Calibration Selection Guide (1.83 MB)
application/pdf iconIndustrielle Temperatur-Kalibrierung Produktübersicht (German) (3.49 MB)
application/pdf iconGuide de sélection d'étalonnage industriel (French) (3.99 MB)
application/pdf iconGúia de selección de equipos para calibraciones industriales (Spanish) (3.45 MB)
application/pdf iconGuide alla selezione di strumenti per calibrazione industriale (Italian) (3.52 MB)
application/pdf iconУказатель приборов для промышленной калибровки (Russian) (3.59 MB)
Application Notes
application/pdf iconInfrared Temperature Calibration 101 (English)
application/pdf iconEinführung in die Infrarot-Temperaturkalibrierung 101 (German)
application/pdf iconEtalonnage en températures infrarouges 101 (French)
application/pdf iconCalibración de temperatura infrarroja 101 (Spanish)
application/pdf iconInfrared Thermometer Calibration -- A Complete Guide (2.04 MB)
application/pdf iconInfrared Thermometer Calibration -- A Complete Guide (1.88 MB)
Data Sheets
application/pdf iconTemperature Calibration Silver CarePlan Data Sheet (606.84 KB)
Software
IR Configuration Utility v1.0
FAQs
IR Configuration Utility
Papers / Articles
application/pdf iconDetermining Size of Source for Handheld Infrared Thermometers
application/pdf iconDetermining Size of Source for Handheld Infrared Thermometers – Theory and Practice
application/pdf iconEmissivity – The Crux of Accurate Radiometric Measurement
application/pdf iconInfrared Calibration Development at Fluke Calibration
application/pdf iconInfrared Uncertainty Budget Determination in an Industrial Application
application/pdf iconMetrology 101: Infrared Thermometer Calibration (454.76 KB)
application/pdf iconTraceability and Quality Control in a Radiation Thermometry Laboratory (525.27 KB)
application/pdf iconTraceability and Quality Control in a Radiation Thermometry Laboratory (1.94 MB)
application/pdf iconUncertainty Budgets for IR Temperature Measurement – An Overview
Virtual Demos
418X Virtual Demo
Video
Emissivity Makes a Temperature Difference Video
Recorded Web Seminars
How to Calibrate an IR Thermometer
Product Catalogs
application/pdf iconIndustrial Temperature Calibration Selection Guide (1.83 MB)
application/pdf iconIndustrielle Temperatur-Kalibrierung Produktübersicht (German) (3.49 MB)
application/pdf iconGuide de sélection d'étalonnage industriel (French) (3.99 MB)
application/pdf iconGúia de selección de equipos para calibraciones industriales (Spanish) (3.45 MB)
application/pdf iconGuide alla selezione di strumenti per calibrazione industriale (Italian) (3.52 MB)
application/pdf iconУказатель приборов для промышленной калибровки (Russian) (3.59 MB)